PLANAR TRANSFORMER DESIGN: WINDING RESISTANCE CALCULATION
The objective of this App Note is to show how to calculate the winding resistances and to compare the value of the AC resistance using an interleaved and non-interleaved winding arrangement for the study its influence in the winding resistance calculation.

Nowadays, planar transformers are commonly used in the design of high frequency power converters due to its advantages, like low profile, excellent thermal characteristics or power density. In the design of the transformer, an important step is the calculation of the winding losses, which depend on the winding AC and DC resistances.


WINDING DC RESISTANCE CALCULATION

Where: 

 is the resistivity

l  is the trace length

A is the trace section      A= Thickness¬∑Width


WINDING AC RESISTANCE CALCULATION

Where:

 is the ratio of the layer thickness:   

h is the trace thickness

 is the skin depth

m is the ratio of the proximity effect influence:

* This calculation gives an approximated AC resistance, and does not consider the porosity factor and high frequency effects related to the currents distribution that cause an extra winding losses.

AC RESISTANCE CALCULATION USING AN INTERLEAVED AND NON-INTERLEAVED WINDING ARRANGEMENTS

Transformer specifications

AC Resistance comparison

CONCLUSION

The winding AC and DC resistance calculation is a very important part of the magnetic design procedure for determining the total power losses. In order to obtain the optimum AC and DC resistances value, a lot of iterations are needed, covering, among other things, all the possible layers distributions or the trace thickness values in planar transformers. Frenetic, thanks to its AI technology, is able to determine the optimum design faster than classical methods.